Dry Gas Filters Pressure Max 6 Bar (Aluminium Body)
“GF” series cartridge type filters; It is designed to hold dust, dirt, rust and other solid particles. It can be used in front of pressure reduction and measurement stations, gas train lines, power plants and combustion control systems. Filters are suitable for filtration of natural gas, LPG and other non-corrosive gases. (DIN 3840 and EN 12516.). It is designed and manufactured in accordance with 2014/68 / EU CE directives.
About Product
“GF” series cartridge type filters; It is designed to hold dust, dirt, rust and other solid particles. It can be used in front of pressure reduction and measurement stations, gas train lines, power plants and combustion control systems. Filters are suitable for filtration of natural gas, LPG and other non-corrosive gases. (DIN 3840 and EN 12516.). It is designed and manufactured in accordance with 2014/68 / EU CE directives.
Gas Filters are designed and manufactured in accordance with DIN 3840 EN 12516 rules and 2014/68 / EU directives.
- All filters are suitable for outdoor use.
- Easy and fast cartridge change.
- High filtration capability and low-pressure loss.
- Optional differential pressure manometer can be installed.
Technical Specifications
Technical Specifications | |
Maximum permissible pressure(PS) | 6 bar |
Nominal Size | Threaded Conn. 1/2'' - 3/4'' - 1'' - 11/4'' - 11/2'' - 2'' Flanged Conn. DN 25-32-40-50-65-80-125-150-200-250-300 |
Connections | Threaded series connections: UNI-ISO 7/1 Flanged series connections: ISO 7005 or ANSI Class 150 RF |
Temparature Range | Operating and ambient temperature -40 °C to +70 °C |
Body Cover Materials Filter Element | AlSiCast Metallic grid and textile filter element NBR |
Approximate ΔP value for filter cartridge change | 20 mbar |
ΔPmax limit for soiled filter cartridges | 100 mbar |
Filtration efficiency | 10 or 20 or 50μm |
Filter Area | see catalogue |
Pressure Volume | see catalogue |
Testing | DIN 3386 |
CE-mark acc. to PED and PIN-Nr. | CE1783 612-PED-062/2014-01 |
Explosion protection | Mechanical components of regulator do not contain a potential ignition source, thus do not fall in limits of ATEX 95 (94/9/EG). (Used electronic accessories comply with ATEX-demands.) |